Delta RMC151 User Manual
Page 146
RMC70/150 and RMCTools User Manual
514 1014
Part Offset = 1014
-
515 507
Part Length = 507
-
516 2504
Total Length = 2504
-
517 Y
1010
Y
1010
1014
: :
:
:
1023 Y
1516
Y
1516
1520
After writing part #3 and issuing the Curve Add command, the user should wait for the
Curve Status at Variable 512 to become 2 (if you are looking in RMCTools, make sure to
look in the Monitor tab of the Variable Table Editor), indicating that the RMC has
completed processing the part.
Part #4
Variable Data
Description
Curve Data
Offset
512 0
Status = 0
-
513 20
Format = 20
-
514 1521
Part Offset = 1521
-
515 507
Part Length = 507
-
516 2504
Total Length = 2504
-
517 Y
1517
Y
1517
1521
: :
:
:
1023 Y
2023
Y
2023
2027
After writing part #4 and issuing the Curve Add command, the user should wait for the
Curve Status at Variable 512 to become 2 (if you are looking in RMCTools, make sure to
look in the Monitor tab of the Variable Table Editor), indicating that the RMC has
completed processing the part.
Part #5
Variable Data
Description
Curve Data
Offset
512 0
Status = 0
-
513 20
Format = 20
-
514 2028
Part Offset = 2028
-
515 476
Part Length = 476
-
516 2504
Total Length = 2504
-
517 Y
2024
Y
2024
2028
: :
:
:
992 Y
2499
Y
2499
2503
After writing part #5 and issuing the Curve Add command, the user should wait for the
Curve Status at Variable 512 to become 3 (if you are looking in RMCTools, make sure to
look in the Monitor tab of the Variable Table Editor), indicating that the RMC has
completed processing the curve. Notice that the curve data point numbering begins with
0, and therefore 2499 is the last point of the 2500-point curve.
126
Delta Computer Systems, Inc.