beautypg.com

Delta RMC151 User Manual

Page 1143

background image

9 Register Reference

address of the register to

save the value coming in

on the SSI input.

F144+n:20 73747

+512 x n

E1_08210

+512 x n

DWORD %MD144+n.20 DWORD Read Only Channel 0 SSI Status

[Applies only to SSI

Output and SSI Register

Input modes]
Bit 0 - Clock Wire Fault
Wire Break for Clock

inputs, Short for Clock

outputs.
Bit 1 - Data Wire Fault
Wire Break for Data

inputs, Short for Data

outputs.
Bit 2 - No Master

Detected - Two or

more loops (SSI Slave

modes only)
No master device is

clocking SSI data--two or

more loops in a row.
Bit 3 - No Slave

Detected (SSI Register

Input only)
Transducer or RMC not

responding with data.
Bit 4 - No Master

Detected - One or

more loops (SSI Slave

modes only)
This status register

indicates that no clocked

data was detected this

loop time, even if this is

the first loop this

occurred. Notice that this

can be expected behavior

when the loop times are

not synchronized.

F144+n:24 73749

+512 x n

E1_08212

+512 x n

DWORD %MD144+n.24 DWORD Read/Write Channel 1 Mode

Bits 0-3 - Channel

Mode
0 = Quadrature Axis

Input
1 = SSI Axis Input
2 = SSI Register Input
3 = SSI Output
Bit 4 - SSI

Master/Slave
[Applies only to SSI

Output and SSI Register

Input modes]

deltamotion.com

1123

This manual is related to the following products: