7 Hardware

1. If Drive 1 is assigned to an axis that has an input (i.e. isn't output-only), then that

axis will own the Axis 1 LED.

2. Otherwise, if a reference input axis (no output) uses input 1, then that axis will own

the Axis 1 LED.

3. Otherwise, if Drive 1 is assigned to an output-only axis, then that axis will own the

Axis 1 LED.

LED Colors

State

Description

Steady

Off

No power or the output/input is not assigned to an axis.

Steady

Green

The axis is either in closed loop control or is a reference axis. The axis is

not halted.

Flashing

Green

The output is in open loop and the axis is not halted (not possible for

reference axes).

Flashing

Red

A Closed Loop Halt or External Halt has occurred because an error bit is set

(not possible for reference axes). The LED will not turn red due to a halt

caused by a halt command.

Steady

Red

An Open Loop Halt or Direct Output Halt has occurred because an error bit

is set (for reference axes, any halt has occurred). The LED will not turn red

due to a halt caused by a halt command.

7.3.9. DI/O Module

7.3.9.1. DI/O Module (RMC150)

The Discrete I/O module for the RMC150 contains eight discrete outputs and eighteen discrete

inputs. The discrete I/O are compatible with signals ranging from 5 to 24 VDC.
Discrete I/O can be used for the following purposes:

Turn outputs on and off with commands

Use discrete I/O in User Programs

Use discrete inputs to start User Programs

Physical Limit Inputs

Part Number

The DI/O Module can be placed in slot 0, 3, 4, or 5 of the RMC150 backplane. However,

because the backplane connector of slot 0 (the leftmost slot) is different from that of slots

3-5, the part number of a DI/O module for slot 0 differs from a DI/O module for slots 3-5.
If placed in slot 0, the part number is DI/O. If placed in slots 3, 4, or 5, the part number

is Dn, where n is the number of D modules. Multiple Discrete I/O modules can be placed

in the same rack.

Slot Part Number

0 DI/O

This must be added to the end of the part

number, for example RMC150E-M1-H2-DI/O.

3-5 Dn

where x is the number of DI/O modules, for

example RMC150E-M1-D2.

deltamotion.com

667