Delta RMC151 User Manual
Page 665
7 Hardware
Slot # 0
1
2
3
4
5
Slot Descriptions
Slot #
Slot 0
Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
Alternate
Name
Comm
Slot
CPU Slot
Sensor Slot
1
Sensor Slot
2
Sensor Slot
3
Sensor Slot
4
Possible
Modules
Analog (A)
Analog (G)
Analog (H)
MDT (M)
SSI (S)
Quad (Q)
Resolver(R)
DI/O
Universal
I/O
SO Module
Analog (A)
Analog (G)
Analog (H)
MDT (M)
SSI (S)
Quad (Q)
Resolver(R)
DI/O
Universal
I/O
SO Module
Analog (A)
Analog (G)
Analog (H)
MDT (M)
SSI (S)
Quad (Q)
Resolver(R)
DI/O
Universal
I/O
SO Module
Analog (A)
Analog (G)
Analog (H)
MDT (M)
SSI (S)
Quad (Q)
Resolver(R)
DI/O
Universal
I/O
SO Module
Module Descriptions
Module
Slots Description
CPUs
RMC150E
1
CPU module with 10/100 Ethernet, USB Monitor Port, 2 discrete
outputs, 2 discrete inputs.
1
CPU module with 10/100 Ethernet, USB Monitor Port, 2 discrete
outputs, 2 discrete inputs, and Pressure/Force dual-loop enabled.
Sensor Modules
Analog (A)
2-5
4 analog inputs (voltage or current), no analog outputs
2-5
2 analog inputs (voltage only), 2 analog outputs
2-5
4 analog inputs (voltage or current), 2 analog outputs
2-5
2 MDT (Magnetostrictive Displacement Transducer) inputs, 2
analog outputs
2-5
2 SSI (Synchronous Serial Interface) inputs, 2 analog outputs
2-5
2 Quadrature encoder inputs (5V differential A, B, Z), 2 analog
outputs, home inputs, travel limit inputs, enable outputs.
0, 2-
5
2 resolver inputs, 2 analog outputs
SO Module
2-5
1 SSI input, 1 SSI Output which retransmits the SSI input data, 2
analog outputs
Other
DI/O
0, 2-
5
8 discrete outputs, 18 discrete inputs
0, 2-
5
2 analog inputs, 6 discrete I/O, 2 high-speed Quadrature/SSI
channels
0
PROFIBUS communication
deltamotion.com
645