Pressure/force limit is a special type of pressure or force control. With pressure or force

limit, the pressure or force is limited during the position or velocity motion of an axis.
Pressure/force limit cannot be used simultaneously with pressure/force control. If the axis

is in pressure/force limit, and a command is issued that puts the axis in pressure/force

control, the pressure/force limit will no longer be active and the axis will start controlling

the pressure or force. However, the Pressure/Force Limit Enabled status bit will still be

set, and if the axis exits pressure/force control, it will resume pressure/force limit.
Determining Whether Pressure/Force Limit is Required

If you want to transition between position and pressure or force control, and each

control mode does not depend on the other, then you probably do not need pressure

or force control.

If you want to transition between position and pressure or force control, but you want

to make sure the axis will not exceed a certain position while controlling

pressure/force, you probably need pressure/force limit. However, you can use

pressure/force control and monitor the other values from a user program to handle

error conditions.

If you want to perform position or velocity motion, but limit the pressure or force

during the motion, then you probably need pressure or force limit.

If you will be using pressure/force limit, see the Pressure/Force Limit topic. If you will be

using pressure/force control, continue reading this topic.

Enter Pressure or Force Control

To enter pressure or force control, issue one of the following commands. Notice that

these commands will enter pressure/force control, not pressure/force limit.

Hold Current Pressure/Force (19)

This command will enter pressure or force control and hold the current pressure or

force. This command is a good choice if your axis is stopped or moving slowly.

Enter Pressure/Force Control (Time) (45)

This command will enter pressure or force control and then ramp to the requested

pressure or force within the specified time.

Enter Pressure/Force Control (Auto) (44)

This command will enter pressure or force control and ramp to the requested pressure

or force. The ramp is automatically calculated based on the current rate of change of

the Actual Pressure or Force. This command is designed to be used when the system is

moving and the Actual Pressure or Force is rising quickly, which indicates the axis is

encountering the resisting pressure or force. This command can provide a very smooth

transition from position to pressure control while the system is moving.

Enter Pressure/Force Control (Rate) (46)

This command will enter pressure/force control and then ramp to the requested

pressure/force at the requested rate and acceleration.

When the axis is in pressure or force control, the Pressure/Force Control status bit will be

set.

Controlling Pressure or Force

Once the axis is in pressure or force control, you can issue any of the pressure/force

commands, including the commands that enter pressure/force control. For example, you

can ramp the pressure up or down, or perform a sinusoidal profile, or follow a spline.
For details on each command, see the respective help topics.

Ramp Pressure/Force (Rate) (18)

Hold Current Pressure/Force (19)

Ramp Pressure/Force (S-Curve) (41)

Ramp Pressure/Force (Linear) (42)