8 Command Reference

Target Position (2)

Description

This command is an advanced command. Do not use it unless you specifically intend to

use the Position I-PD control mode. If you want to make a basic relative motion move,

use the Move Relative (21) command instead.
This command is identical to the Move Absolute (I-PD) (28), except that the final

Command Position is computed by adding the Requested Distance to the current value

of the quantity specified in the Relative To parameter. The current value is the value at

the time the RMC received the command.
Relative To Options:

Command Position (0)

The final Command Position is computed by adding the Requested Distance to the

current Command Position.

Actual Position (1)

The final Command Position is computed by adding the Requested Distance to the

current Actual Position.

Target Position (2)

The final Command Position is computed by adding the Requested Distance to the

current Target Position.


See the Move Absolute (I-PD) (28) topic for more details.

8.4.6. Gearing

8.4.6.1. Command: Gear Absolute (25)

Supported Axes: Position Control Axes

Supported Control Modes: Position PID, Position I-PD

Firmware Requirement: 2.70 or newer

Hardware Limitations: RMC75S: versions 2.1D or newer only

RMC75P: versions 2.1E or newer only
RMC75E: No limitations
RMC150E: No limitations


See the Commands Overview topic for basic command information and how to issue

commands from PLCs, HMIs, etc.

Command Parameters

# Parameter Description

Range

1 Master Register

Note: See Specifying a Register Address below.

Valid RMC register

2 Master Point A (pu)

Any REAL number

3 Master Point B (pu)

Any REAL number

4 Slave Point A (pu)

Any REAL number

deltamotion.com

725