How to Find: Address Selection Tool → Controller → Communication Settings →

Ethernet

Data Type: DWORD

Accessibility: Read Only


This register indicates the state of the Controlling Connection for EtherNet/IP I/O and

PROFINET communications. For more details, see Handling Broken EtherNet/IP I/O

Connections and Handling Broken PROFINET Connections.
Bit Tag Name

Description

0

_Enet.CCStatus.Active

Controlling Connection Active
This bit is set as long as a Controlling Connection is currently

active. If the connection is closed or timed out, this bit will

be cleared.

1

_Enet.CCStatus.TimedOut Controlling Connection Timed Out

This bit is set when a Controlling Connection timed out.

Notice that this is only one method of a controlling

connection being closed (another example is the PLC

intentionally closing it). This bit is cleared when the

Controlling Connection is re-opened. The user can look for

the rising edge of this bit in the Program Triggers to respond

to a time-out.

A time-out can occur when the cable is disconnected, or

when the client is powered off or reset.

PROFINET controlling connections do not use this bit. Only

the Active bit can be used for PROFINET controlling

connections.

9.2.3.4. Controlling PLC Status

Type: Communications Register

RMC70 Address: %MD21.24. See Register Map topic for other address formats.

RMC150

Address:

%MD45.24. See Register Map topic for other address formats.

System Tag: _Enet.PLCStatus

How to Find: Address Selection Tool → Controller → Communication Settings →

Ethernet

Data Type: DINT

Accessibility: Read Only


This register indicates the state of the controlling PLC via EtherNet/IP I/O and PROFINET

communications. For more details, see Handling Broken EtherNet/IP I/O Connections and

Handling Broken PROFINET Connections.
This register (DINT data type) can hold one of three values:

0: Unknown (applies whenever no controlling connection is active)
1: Run

1004

Delta Computer Systems, Inc.