3 Controller Features

If the axis is part of a Halt Group, it starts the same level of halt on all axes in the

group. See the Halt Group Number topic for more details.

The RMC immediately stops all Tasks by default. This setting can be changed on the

Programming Properties dialog.

Caution:

If you disable this feature, User Programs may still be running after a halt occurs

and may cause motion on the axis. Make sure you handle the halt condition safely.

One method is to create a User Program to handle the halt condition and use the

Program Triggers to start the User Program when the Halt bit turns on.

Pressure/Force Control
The Closed Loop Halt and Open Loop Halt do remove the axis from pressure or force

control. The Direct Output Halt (3) and Fault Controller (8) commands will.

Triggering a Halt

Halts can then be triggered in two ways:

Issue a Command

By issuing commands (except External Halt). See each halt command topic for details.

1.

Halt

Command

Closed Loop Halt

Closed Loop Halt (1)

Open Loop Halt

Open Loop Halt (2)

Direct Output Halt Direct Output Halt (3)

2.

Auto Stop

Auto Stops automatically trigger a halt when an Error Bit is set. The Auto Stops can be

configured to trigger any level of halt, or Status Only, for each individual Error bit. See

the Auto Stops topic for details.

Fault Controller (8) Command

The Fault Controller (8) command will halt all the axes.

3.4.2. External Halt

The External Halt is not intended to actually halt motion; rather, it is intended only to signal a

master controller, such as a PLC, that an axis should be halted, and the PLC should then take

care of the halting. The External Halt does not affect motion in any way. An External Halt will

not stop any user programs. The External Halt is one of the four types of RMC Halts.
When an External Halt occurs, only the following happens:

The External Halt status bit is set.

If the axis is part of a Halt Group, it sets the External Halt bit on all axes in the group.


If the External Halt was triggered because of the occurrence of a No Transducer or Transducer

Overflow error, which in themselves may severely impact motion, the feedback value will be

held at its last valid value.

Triggering an External Halt

An External Halt can only be triggered via Auto Stops.

After a Halt has Occurred