6 Communication

The Basic+ mode uses two fixed-length blocks of data: the Command Block and the

Response Block.
Command Block
The Command block is a block of 8 contiguous 32-bit output registers. These registers are

sent from the PLC or PC to the RMC.

The Command Block has the following structure:

Register
Number

Data
Type


Description

Command Area:

Registers 0 - 5 are used for issuing commands to the RMC70. See

Issue a Single Command and Issue Simultaneous Commands

below for details on using these registers.

0

Integer Command Register

Bit

Bit Description

31

Command Request

30

Deferred Command

29

Deferred Command

20-28 Reserved
19

Axis 3 Select

18

Axis 2 Select

17

Axis 1 Select

16

Axis 0 Select

8-15

Reserved

7-0

Command Number

1

Float

Command Parameter 1

2

Float

Command Parameter 2

3

Float

Command Parameter 3

4

Float

Command Parameter 4

5

Float

Command Parameter 5

Data Channel 0:

Registers 6 and 7 are used for reading and writing to any register in

the RMC70. See Read from the RMC70 and Write to the RMC70

for details on using these registers.

6

Integer Read/Write Register

Bit

Bit Description

31

Read/Write

30

Read/Write Request

16-29 Reserved
15-8

R/W Address File

7-0

R/W Address Element

deltamotion.com