See the Commands Overview topic for basic command information and how to issue
commands from PLCs, HMIs, etc.
Command Parameters
# Parameter Description
Range
1 Address
Note: See Specifying a Register Address below.
unsigned integer
Description
Note: Delta does not recommend using this command. PLCs can read any register directly
without needing to send this command. In a user program, use the Expression (113)
command to directly access registers.
This command copies the register pointed to by the Address into the axis' Read
Response register.
Specifying a Register Address
When issuing this command from anywhere other than RMCTools, the addresses in the
Address command parameter must be entered as an integer value.
RMC addresses are represented in IEC format as:
%MDfile.element, where file = file number, and element = element number.
Use the following equation to convert a register address to integer format, N:
N = file * 4096 + element
Example:
Register address %MD8.33 is 8*4096 + 33 = 32801.
Why Bother?
This command is used with certain communication types. If the communications is set up
to continuously return the Read Response register, then issuing this command will allow
you to read whatever register you want. This is a good way of accessing more registers
for communication types that are set up to only return certain registers.
8.6.10. Command: Write Register (112)
Supported Axes: All
Firmware Requirement: 1.00 or newer
See the Commands Overview topic for basic command information and how to issue
commands from PLCs, HMIs, etc.
Command Parameters
# Parameter Description
Range
1 Address
Note: See Specifying a Register Address below.
unsigned integer
2 Value
Description