beautypg.com

27 display off mode output register (door) – Renesas SH7781 User Manual

Page 920

background image

19. Display Unit (DU)

Rev.1.00 Jan. 10, 2008 Page 890 of 1658
REJ09B0261-0100

19.3.27

Display Off Mode Output Register (DOOR)

The display off mode output register (DOOR) sets the display data output when the display is
turned off. The value is retained during power-on reset and manual reset.

R/W:

Internal update:

R/W:

Internal update:

16

17

18

19

20

21

22

23

24

25

26

27

28

29

31

30

Bit:

Initial value:

R

R

R/W

R/W

R/W

R/W

R/W

R/W

R

R

R

R

R

R

R

R

O

O

O

O

O

O

0

0

0

0

0

0

0

0

0

0

DOR

R

R

R/W

R/W

R/W

R/W

R/W

R/W

R

R

R/W

R/W

R/W

R/W

R/W

R/W

O

O

O

O

O

O

O

O

O

O

O

O

0

0

0

0

DOB

DOG

0

1

2

3

4

5

6

7

8

9

10

11

12

13

15

14

Bit:

Initial value:

Bit Bit

Name

Initial
Value R/W

Internal
Update Description

31 to 24

⎯ All

0

R

⎯ Reserved

These bits are always read as 0. The write value
should always be 0.

23 to 18 DOR

Undefined R/W

Yes

Display Off Mode Output Red

Red-color display data for output when the
display is off should be set.

17, 16

⎯ All

0

R

⎯ Reserved

These bits are always read as 0. The write value
should always be 0.

15 to 10 DOG

Undefined R/W

Yes

Display Off Mode Output Green

Green-color display data for output when the
display is off should be set.

9, 8

⎯ All

0

R

⎯ Reserved

These bits are always read as 0. The write value
should always be 0.

7 to 2

DOB

Undefined R/W

Yes

Display Off Mode Output Blue

Blue-color display data for output when the
display is off should be set.

1, 0

⎯ All

0

R

⎯ Reserved

These bits are always read as 0. The write value