16. Watchdog Timer and Reset (WDT)
Rev.1.00 Jan. 10, 2008 Page 779 of 1658
REJ09B0261-0100
16.5.3
Manual Reset by Watchdog Timer Overflow
The time period taken by manual reset on watchdog timer overflow (WDT manual reset holding
time) is equal to or more than 30 cycles of the peripheral clock (Pck).
The transition time from watchdog timer overflow to the manual reset state (WDT reset setup
time) is equal to or more than eight cycles of the peripheral clock (Pck).
(1)
Manual Reset Caused by Watchdog Timer Overflow during Normal Operation
The timing of indicating the reset state or normal operation on the STATUS[1:0] pins is
synchronous with the peripheral clock (Pck), and is therefore asynchronous with the clocks input
from the EXTAL pin and the CLKOUT pin.
WDT reset setup time
WDT manual reset holding time
WDT overflow
signal
CLKOUT
output
STATUS[1:0]
output
HH (reset)
LL (normal)
LL (normal)
EXTAL
input
CLKOUTENB
output
MRESETOUT
output
Figure 16.8 STATUS Output by Manual Reset Caused by WDT Overflow
during Normal Operation