beautypg.com

Renesas SH7781 User Manual

Page 1114

background image

21. Serial Communication Interface with FIFO (SCIF)

Rev.1.00 Jan. 10, 2008 Page 1084 of 1658
REJ09B0261-0100

5. When modem control is enabled, the

SCIF_RTS signal is output when SCFRDR is empty.

When

SCIF_RTS is 0, reception is possible. When SCIF_RTS is 1, this indicates that

SCFRDR contains bytes of data equal to or more than the

SCIF_RTS output active trigger

count. The

SCIF_RTS output active trigger value is specified by bits 10 to 8 in SCFCR. For

details, see section 21.3.9, FIFO Control Register n (SCFCR). In addition,

SCIF_RTS is also 1

when the RE bit in SCSCR is cleared to 0.

Figure 21.14 shows an example of the operation when modem control is used.

D0

D1

D2

D7 0/1 1

0

0

Serial data

SCIF_RXD

SCIF_RTS

Start
bit

Parity
bit

Stop
bit

Start
bit

Figure 21.14 Example of Operation Using Modem Control (

SCIF_RTS)

(Only in Channels 1 and 2)