beautypg.com

Renesas SH7781 User Manual

Page 1180

background image

22. Serial I/O with FIFO (SIOF)

Rev.1.00 Jan. 10, 2008 Page 1150 of 1658
REJ09B0261-0100

(8)

Synchronization-Pulse Output Mode at End of Each Slot (SYNCAT Bit = 1)

Synchronous pulse method, falling edge sampling, slot No.0 used for left-channel data, slot No.1
used for right-channel data, slot No.2 used for control channel 0 data, slot No.3 used for control
channel 1 data, and frame length = 128 bits

TRMD[1:0] = 00 or 10,
TDLE = 1,
RDLE = 1,
CD0E = 1,

REDG = 0,
TDLA[3:0] = 0000,
RDLA[3:0] = 0000,
CD0A[3:0] = 0010,

FL[3:0] = 1110 (frame length: 128 bits),
TDRE = 1,
RDRE = 1,
CD1E = 1,

TDRA[3:0] = 0001,
RDRA[3:0] = 0001,
CD1A[3:0] = 0011

Slot No.0

Slot No.1

Slot No.2

Slot No.3

Slot No.4

Slot No.5

Slot No.6

Slot No.7

Specifications:

1 frame

SIOF

_SCK

SIOF

_RXD

SIOF

_TXD

SIOF

_SYNC

L-channel

data

R-channel

data

Control

channel 0

Control

channel 1

Figure 22.20 Transmit and Receive Timing (16-Bit Stereo Data)