Link type - loop, E.4.8 link type - loop – Delta RMC101 User Manual

Page 905

background image

Appendix E: Event Step Link Reference

E-15

Using without the Link Type and Link Value Dialog Box

1. Enter a 'J' for the Link Type.

2. Enter a 0 in the Link Value.

E.4.8 Link Type - Loop

Link
Type:

LoopStart (#, hex 0x23, dec 35)
LoopEnd (-, hex 0x2D, dec 45)

Link
Value:

Number of loop iterations

Range:

0 to 65,535

Note:

This feature is available only in RMC100 CPU firmware version 19980811 and later.

Note:

This link type cannot be used with the Poll (?) command.


The LoopStart (#) and LoopEnd (-) link types are used together to create loops in the Event Step
table. The Link Value of the LoopStart link type indicates how many iterations you want through
the loop. The LoopStart link type jumps immediately to the step indicated by the Link Next. This
should typically indicate the step of the LinkEnd link type.

The LoopEnd link type tests the loop counter to see if it zero. If it is zero then the next step—not
the step specified in the Link Next field—will be executed. If the loop counter is not zero then it is
decremented by one and the step specified in the Link Next field is jumped to. The Link Value on
the LoopEnd link type is ignored and should be set to zero (0).

Example:

The following example executes steps 2 though 5 three times. After the third loop step 7 is executed.

Step 1

Step 2

Step 3

Step 4

Step 5

St

Mode

0x0081

0x0081

0x0081

0x0081

0x0081

0x0

Accel

100

100

100

100

100

Decel

100

100

100

100

100

Speed

10000

10000

10000

10000

10000

10

Command

Value

4000

10000

10000

4000

4000

4

Command

G

G

Commanded

Axes

Default

Default

Default

Default

Default

De

Link Type

LoopStart

BitsON

DelayMS

BitsON

DelayMS

Loop

This manual is related to the following products: