Ssi led indicators, Ssi led indicators -74, 4 ssi led indicators – Delta RMC101 User Manual
Page 618
RMC100 and RMCWin User Manual
6-74
2 = 0.01 mm (10 µm)
3 = 0.05mm (50 µm)
4 = 0.1 mm (100 µm)
5 = 0.02 mm (20 µm)
6 = 0.002 mm (2 µm)
This setting does not affect the SSI Configuration dialog, but must be taken into account when
setting the Scale.
d: Performance
1 = Standard
This setting does not affect the Configuration word.
e, f: Scale Orientation
00 = Forward-acting
01 = Reverse-acting
02 = Forward-acting, Synchronized
This setting does not affect the Configuration word.
Note:
It is highly recommended that a Synchronized transducer (Scale Orientation of 02) be
selected. This ensures that the time between position samples matches the control loop time of
the RMC controller. If the transducer is not synchronized, the sample time may not match and
make precise speed control difficult.
See also:
SSI Overview
SSI Wiring
SSI LED Indicators
SSI Specifications
6.6.4 SSI LED Indicators
The two LEDs above the Drive connector on the RMC’s SSI interface card are axis status LEDs.
These LEDs will reflect the operational status of their corresponding axis according to the
following table.
LED Action
Axis Status
Continuous Red
One or more of these errors have