RMC100 and RMCWin User Manual

5-186

:

:

2553 + n

Event Step for Axes n (0-7) on Input 15
Falling Edge

Status Map Registers:
These registers can be read or written, although you should not manually change the values in
this table. You should use the Status Map Editor to change this table and then download it to the
RMC. You may then read this table into the PLC and send the table to the RMC each time the
PLC is restarted.

Modbus

Address

Register Description

2561-

2592

Status Map Entries

Plot Type Registers:
The plot type registers can be read or written. The values that are read indicate the extra plot
information in the current graph. The values written to these registers tell the controller which
extra plot information to obtain on the next plot. For these registers, the following values are used:

• 0: Extra position precision

• 1: Command and Command Value

• 2: Event Step and Link Value

• 3: Raw Transducer Counts

• 4: Internal Target and Actual Speeds

• 5: Integral Drive

For more information on these four types of plot information, see Selecting the Data to Plot and
Reading Plots from the Communication Module.

Modbus

Address

Register Description

2625

Axis 0 plot type

2626

Axis 1 plot type

2627

Axis 2 plot type

2628

Axis 3 plot type

2629

Axis 4 plot type

2630

Axis 5 plot type