Communication Tasks 5.9

Communications

5-291

• You can simultaneously download splines to all spline-capable axes at one time.
• It is important that you avoid trying to download a spline from RMCWin’s curve tool while

downloading through the Spline Download Area.

5.9.3 Parameter Error Values

The Parameter Error bit in each axis’s Status word is used to indicate a wide range of problems.
This bit indicates that, either directly or indirectly, a command given to the RMC by the user
cannot be executed as requested. However, it is not always obvious as to exactly what was
wrong with the issued command. Therefore, the RMC has Last Parameter Error registers that
hold an integer value for each axis. This integer value latches to the value of the last parameter
error received. Therefore, it will not be cleared even if the Parameter Error bit itself clears.

RMCWin reads these registers when it detects the Parameter Error bit on an axis and it reports a
text message corresponding to that error number. By using the Windows | Parameter Error List,
the user can review the last parameter errors on each axis and receive error-specific help.

It is also possible to read the Last Parameter Error Registers from your PLC when using the
RMC’s Ethernet, Modbus Plus, or PROFIBUS (in Message Mode) communication modules. See
the appropriate RMC Register Map topic for the addresses of these registers.

The purpose of this topic is to list the possible values you may receive from these registers, list a
short description of each, and provide a link to a more detailed discussion on the problem. Click
on the description text to jump to the topic with details on the error.

Value

Description

200

Target position moved outside limits

210

Flash contained no data on startup

220

Attempt to go beyond extend limit

221

Attempt to go beyond retract limit

222

Requested drive too large

223

Invalid command value

224

Invalid step number given in "Start Events" command

225

Invalid scale value

226

Extend limit must be greater than retract limit

227

Dead band eliminator out of range

228

Invalid command received

229

Non-existent pressure axis selected in "Config" word

230

Drive transfer percentage out of range

231

Feed forward terms must have the same sign

232

Resetting the position would cause a position overflow

233

Resetting the position is not allowed in this state

234

Axis must be initialized to use this command

235

Cannot overflow command pressure

236

Invalid MODE bits set for this command