Delta RMC101 User Manual
Page 394
RMC100 and RMCWin User Manual
5-144
Reserved Registers:
Reading these values will return zero, and writes are ignored.
Omron
Address
Register Description
D02664-
D12287
Unused
Spline Download Area:
These registers are write only. Reading them will return zero. This area is used to download
intervals and points in a spline. This is a much more efficient alternative to using individual New
Spline Point (X) and Set Spline Interval/End Segment (T) commands. For details on using this
Spline Download Area, see Downloading Splines to the RMC.
Note:
The Omron CV500 and CVM1-CPU01 PLCs are limited to addressing D0 to D8191, and
therefore cannot use the Spline Download Area.
Omron
Address
Register Description
D12288-
D16383
Spline Download Area
Plot Registers:
These registers can only be read; writes are ignored.
Note:
Reading plots is not a trivial task; for further details, see Reading Plots from the
Communication Module.
Omron Address
Register Description
E0_00000-
E0_06143
Plot data for axis 0
E1_00000-
E1_06143
Plot data for axis 1
E2_00000-
E2_06143
Plot data for axis 2
E3_00000-
E3_06143
Plot data for axis 3
E4_00000-
E4_06143
Plot data for axis 4
E5_00000-
E5_06143
Plot data for axis 5