Delta RMC101 User Manual
Page 403
Ethernet 5.2
Communications
5-153
N17:248 + n
Event Step for Axes n (0-7) on Input 15
Falling Edge
Status Map Registers:
This block of registers is only used by the Modbus Plus and PROFIBUS interfaces. Therefore,
these registers are unused by this Ethernet protocol.
Allen-
Bradley
and SoftPLC
Register Description
N18:0-63
Status Map Entries
Plot Type Registers:
The plot type registers can be read or written. The values that are read indicate the extra plot
information in the current graph. The values written to these registers tell the controller which
extra plot information to obtain on the next plot. For these registers, the following values are used:
• 0: Extra position precision
• 1: Command and Command Value
• 2: Event Step and Link Value
• 3: Raw Transducer Counts
• 4: Internal Target and Actual Speeds
• 5: Integral Drive
For more information on these four types of plot information, see Selecting the Data to Plot and
Reading Plots from the Communication Module.
Allen-
Bradley
and SoftPLC
Register Description
N18:64
Axis 0 plot type
N18:65
Axis 1 plot type
N18:66
Axis 2 plot type
N18:67
Axis 3 plot type
N18:68
Axis 4 plot type
N18:69
Axis 5 plot type
N18:70
Axis 6 plot type
N18:71
Axis 7 plot type
Digital (Discrete) I/O Registers: