Delta RMC101 User Manual
Page 340
RMC100 and RMCWin User Manual
5-90
n
Falling Edge
Status Map Registers:
PLC Support:
D2-250, D4-430, D4-440, and D4-450 (D2-240 excluded)
This block of registers is only used by the Modbus Plus and PROFIBUS interfaces. Therefore,
these registers are unused by Automationdirect.com Ethernet.
V-
memory
Address
Register Description
V6400-
V6437
Status Map Entries
Plot Type Registers:
PLC Support:
D2-250, D4-430, D4-440, and D4-450 (D2-240 excluded)
The plot type registers can be read or written. The values that are read indicate the extra plot
information in the current graph. The values written to these registers tell the controller which
extra plot information to obtain on the next plot. For these registers, the following values are used:
• 0: Extra position precision
• 1: Command and Command Value
• 2: Event Step and Link Value
• 3: Raw Transducer Counts
• 4: Internal Target and Actual Speeds
• 5: Integral Drive
For more information on these four types of plot information, see Selecting the Data to Plot and
Reading Plots from the Communication Module.
V-
memory
Address
Register Description
V6500
Axis 0 plot type
V6501
Axis 1 plot type
V6502
Axis 2 plot type
V6503
Axis 3 plot type
V6504
Axis 4 plot type
V6505
Axis 5 plot type
V6506
Axis 6 plot type
V6507
Axis 7 plot type