beautypg.com

Delta RMC101 User Manual

Page 210

background image

RMC100 and RMCWin User Manual

4-24

Address

Value

Description

14337

9

Number of points in the spline segment.

14338

60000

Point 0 position

14339

60000

Point 1 position

14330

61000

Point 2 position

14331

61500

Point 3 position

14332

61250

Point 4 position

14333

61000

Point 5 position

14334

60750

Point 6 position

14335

61000

Point 7 position

14336

61000

Point 8 position

Downloading with Add Spline Point, Set Spline Interval, and End Spline Segment Commands:
The following commands would be issued in order:

Command

Command

Value

C

0

Clear any pre-existing splines (only needed on
initialization).

T

400

Set the interval for the points that follow to 400
master units.

X

60000

Send leading point.

T

200

Set the interval for the points that follow to 200
master units.

X

60000

Send 1st scanned value.

x

61000

Send 2nd scanned value.

X

61500

Send 3rd scanned value.

x

61250

Send 4th scanned value.

X

61000

Send 5th scanned value.

x

60750

Send 6th scanned value.

T

400

Set the interval for the points that follow to 400
master units.

This manual is related to the following products: