Ssi scaling, Ssi scaling -76, 6 ssi scaling – Delta RMC101 User Manual
Page 620
RMC100 and RMCWin User Manual
6-76
Clock frequency
220 kHz
Cable type
Twisted pair, shielded
Cable length
maximum
Transducer dependent (approx. 300-600
ft)
ESD protection
15 kV
Resolution
Transducer dependent (up to 2 mm or
approximately 0.00008" for MDTs)
Count encoding
Binary or Gray Code
Count data length
4 to 32 bits
Drive Outputs
Range
±10 V @ 5 mA (2 kW or greater load)
(For current drive, use the VC2100
accessory:
±10 mA to ±200 mA in 10 mA steps)
Tolerance
At 10 V: +200 mV, -100 mV
At 0 V: ±50 mV
At -10 V: +100 mV, -200 mV
Resolution
12 bits
Output isolation
750 VDC, optically isolated
Overload
protection
One-second short-circuit duration
Overvoltage
protection
Outputs are protected by clamp diodes
See also:
SSI Overview
SSI Wiring
SSI Configuration
SSI LED Indicators
6.6.6 SSI Scaling
Defining the Valid 16-bit Position Range