SSI 6.6
Transducer Interface Modules
6-69
RMC SSI Input
Six-Pin Plug-in Terminal Block
Pin
Function
1
SSI Axis + Clock
2
SSI Axis - Clock
3
SSI Axis Common
4
SSI Axis + Data
5
SSI Axis - Data
6
Case
SSI uses differential line driver (RS422) clock and data signals. Connect both the +Clock and
Clock between the RMC and transducer for the clock signal, and both the +Data and Data
between the RMC and transducer for the data signal.
The power (+24V) and ground is not provided by the RMC, and therefore must be provided
externally to the transducer.
Connect the transducer DC ground to SSI Cmn.
RMC Drive Outputs
Four-Pin Plug-in Terminal Block
Pin
Function
1
Axis 0 Drive
2
Drive
Common
3
Axis 1 Drive