beautypg.com

Delta RMC101 User Manual

Page 613

background image

SSI 6.6

Transducer Interface Modules

6-69

RMC SSI Input

Six-Pin Plug-in Terminal Block

Pin

Function

1

SSI Axis + Clock

2

SSI Axis - Clock

3

SSI Axis Common

4

SSI Axis + Data

5

SSI Axis - Data

6

Case

SSI uses differential line driver (RS422) clock and data signals. Connect both the +Clock and
Clock between the RMC and transducer for the clock signal, and both the +Data and Data
between the RMC and transducer for the data signal.

The power (+24V) and ground is not provided by the RMC, and therefore must be provided
externally to the transducer.

Connect the transducer DC ground to SSI Cmn.

RMC Drive Outputs

Four-Pin Plug-in Terminal Block

Pin

Function

1

Axis 0 Drive

2

Drive
Common

3

Axis 1 Drive

This manual is related to the following products: