RMC100 and RMCWin User Manual
6-62
S1
Sine Input +
S3
Sine Input -
S2
Cosine Input +
S4
Cosine Input -
Case
Controller chassis ground
(shield)
Note:
The RMC case must be mounted to a grounded panel or otherwise grounded to avoid
Transducer Faults when operating at the 16-bit resolution setting.
RMC Drive Outputs
Four-Pin Plug-in Terminal Block
Pin
Function
1
Axis 0 Drive
2
Drive
Common
3
Axis 1 Drive
4
Case
When positive voltage is sent to an axis’s drive, the axis must extend. The extend direction is
defined as the direction that causes the transducer to return increasing counts.
CAUTION:
If the outputs from the RMC are reversed, the axis will be uncontrollable when power is
connected. Confirm that your wiring is correct!