9 softplc's softplc, Using the softplc with the rmc ethernet module, Softplc's softplc -175 – Delta RMC101 User Manual

Page 425

background image

Ethernet 5.2

Communications

5-175

bits that may be useful to some users:

• If bit 1 (value 0x0002) is set, the control loop

is 2 ms, otherwise the control loop is 1 ms.

• If bit 0 (value 0x0001) is set, a sensor DI/O is

present, otherwise there is no sensor DI/O.

Spline Download Area:
These registers are write only. Reading them will return zero. This area is used to download
intervals and points in a spline. This is a much more efficient alternative to using individual New
Spline Point and Set Spline Interval/End Segment commands. For details on using this Spline
Download Area, see Downloading Splines to the RMC.

S7 Address

Register Description

DB192-207

Spline Download Area

Plot Registers:
These registers can only be read; writes are ignored.

Note:

Reading plots is not a trivial task; for further details, see Reading Plots from the

Communication Module.

Each plot data block has 1024 elements.

S7 Address

Register Description

DB208-213

Plot data for axis 0

DB214-219

Plot data for axis 1

DB220-225

Plot data for axis 2

DB226-231

Plot data for axis 3

DB232-237

Plot data for axis 4

DB238-243

Plot data for axis 5

DB244-249

Plot data for axis 6

DB250-255

Plot data for axis 7

5.2.6.9 SoftPLC's SoftPLC

5.2.6.9.1 Using the SoftPLC with the RMC Ethernet Module

SoftPLC is a PC-based control solution that tightly emulates the PLC-5. Therefore, one who
knows how to use the RMC from a PLC-5 should easily be able to get the SoftPLC to

This manual is related to the following products: