Delta RMC101 User Manual

Page 716

background image

RMC100 and RMCWin User Manual

A-64

0X11 0AAA|XXXX|0001|0001 Set

SCALE

0X12 0AAA|XXXX|0001|0010 Set

OFFSET

0X13 0AAA|XXXX|0001|0011 Set

EXTEND LIMIT

0X14 0AAA|XXXX|0001|0100 Set

RETRACT LIMIT

0X15 0AAA|XXXX|0001|0101 Set

PROPORTIONAL GAIN

0X16 0AAA|XXXX|0001|0110 Set

INTEGRAL GAIN

0X17 0AAA|XXXX|0001|0111 Set

DIFFERENTIAL GAIN

0X18 0AAA|XXXX|0001|1000 Set

EXTEND FEED FORWARD

0X19 0AAA|XXXX|0001|1001 Set

RETRACT FEED FORWARD

0X1A 0AAA|XXXX|0001|1010 Set

EXTEND ACCEL FEED FORWARD

0X1B 0AAA|XXXX|0001|1011 Set

RETRACT ACCEL FEED FORWARD

0X1C 0AAA|XXXX|0001|1100 Set

DEAD BAND ELIMINATOR

0X1D 0AAA|XXXX|0001|1101 Set

IN POSITION

0X1E 0AAA|XXXX|0001|1110 Set

FOLLOWING ERROR

0X1F 0AAA|XXXX|0001|1111 Set

AUTO STOP


The command data represents the new parameter value.

Example for PROFIBUS-DP in Compact Mode with Sync:
Suppose you have an RMC100-M1-PROFI, and you would like to set the Extend Limit for both
axes. You would send commands with the following format:

SAR CMND INDX (HEX)

O+1 0000|XXXX|0001|0011 (0X13)

Sets axis 0 Extend Limit

+2 24000 (5DC0)

New Extend Limit value

O+3 0000|XXXX|0001|0011 (0X13)

Sets axis 1 Extend Limit

+4 12000 (2EE0)

New Extend Limit value

Example for Digital I/O:
Suppose you would like to set the Extend Limit for axis 0. You would send commands with the
following format:

Send on Command Strobe going high: