RMC100 and RMCWin User Manual

A-82

+2 150 (0096)

New Proportional Gain value

O+3 0000|XXXX|1101|0101 (0XD5)

Sets axis 1 Proportional Gain

+4 175 (00AF)

New Proportional Gain value

Example for Digital I/O:
Suppose you would like to set the Extend Limit for axis 1. You would send commands with the
following format:

Send on Command Strobe going high:

0001|XXXX|1101|0101 (1XD5)

Set axis 0 Proportional Gain

Receive after Acknowledge:

XXXX|XXXX (XX)

Low byte of requested data

Send on Command Strobe going high:

0000|0000|1001|0110 (0096)

New Proportional Gain value

Receive after Acknowledge:

XXXX|XXXX (XX)

High byte of requested data

A.3.13 Event Step Edit Commands

Format: 0AAA RRRR 1110 NNNN

R Used for Status Area Request

N Used for Command Index described below

A Used only by Communication Digital I/O; 0 for PROFIBUS-DP


These commands let you change an event parameter’s value across a range of steps in a single
scan. The format of the Command Register for the Event Step Edit commands is given below:


1111|11 | |

BIT #5432|1098|7654|3210

-------------------

HEX |SAR |CMND|INDX

VALUE -------------------

0XE0 0AAA|XXXX|1110|0000

Start Step Number (0 to 255)

0XE1 0AAA|XXXX|1110|0001

End Step Number (0 to 255; > E0)