Appendix A: Command Reference

A-73

1111|11 | |

BIT# 5432|1098|7654|3210

-------------------

HEX | |CMND|INDX

VALUE -------------------

0X90 0AAA|XXXX|1001|0000

Get CONFIGURATION

0X91 0AAA|XXXX|1001|0001

Get SCALE

0X92 0AAA|XXXX|1001|0010

Get OFFSET

0X93 0AAA|XXXX|1001|0011

Get EXTEND LIMIT

0X94 0AAA|XXXX|1001|0100

Get RETRACT LIMIT

0X95 0AAA|XXXX|1001|0101

Get PROPORTIONAL GAIN

0X96 0AAA|XXXX|1001|0110

Get INTEGRAL GAIN

0X97 0AAA|XXXX|1001|0111

Get DIFFERENTIAL GAIN

0X98 0AAA|XXXX|1001|1000

Get EXTEND FEED FORWARD

0X99 0AAA|XXXX|1001|1001

Get RETRACT FEED FORWARD

0X9A 0AAA|XXXX|1001|1010

Get EXTEND ACCEL FEED FORWARD

0X9B 0AAA|XXXX|1001|1011

Get RETRACT ACCEL FEED FORWARD

0X9C 0AAA|XXXX|1001|1100

Get DEAD BAND ELIMINATOR

0X9D 0AAA|XXXX|1001|1101

Get IN POSITION

0X9E 0AAA|XXXX|1001|1110

Get FOLLOWING ERROR

0X9F 0AAA|XXXX|1001|1111

Get AUTO STOP


The data returned where the Status Area Request data would be returned is the requested
parameter.

Example for PROFIBUS-DP in Compact Mode with Sync:
Suppose you have an RMC100-M1-PROFI, and you would like to get the Scale from both axes.
You would send commands with the following format:

CMND INDX (HEX)

O+1 0000|0000|1001|0001 (0091)

Requests Scale for axis 0

+2 XXXX|XXXX|XXXX|XXXX (XXXX)

Ignored