Ethernet 5.2

Communications

5-73

(n)

File (f)

0-31

N9

( n - 0 ) x 8

32-63

N10

( n - 32 ) x 8

64-95

N11

( n - 64 ) x 8

96-127

N12

( n - 96 ) x 8

128-159

N13

( n - 128 ) x 8

160-191

N14

( n - 160 ) x 8

192-223

N15

( n - 192 ) x 8

224-255

N16

( n - 224 ) x 8

Note:

On Allen-Bradley PLCs, reads and writes that extend beyond the end of an RMC register

file will continue into the next file or files. This is particularly useful on the ControlLogix, which
allows reading large amounts of data with a single MSG block. For example, by reading 2048
integers starting at N9:0 in the RMC, the entire Event Step table can be read into the
ControlLogix.

The register map for addressing the fields in the event step table is as follows:

Allen-

Bradley

and SoftPLC

Register Description

N9:0

Step 0 Mode Word

N9:1

Step 0 Acceleration

N9:2

Step 0 Deceleration

N9:3

Step 0 Speed

N9:4

Step 0 Command Value

N9:5

Step 0 Command/Commanded Axes

N9:6

Step 0 Link Type/Link Next

N9:7

Step 0 Link Value

Nf:r + 0

Step n (0-255) Mode Word

Nf:r + 1

Step n (0-255) Acceleration

Nf:r + 2

Step n (0-255) Deceleration

Nf:r + 3

Step n (0-255) Speed