Resolver 6.5

Transducer Interface Modules

6-61

This gives a value between -Scale and +Scale

4. The result is compared with the Coordinate Limit to determine if it is within the allowable range

of Position Units. (See the Resolver Scaling topic for the definition of valid range). If it is outside
the valid range then Scale x 2 is added or subtracted to bring it back within range.

Useful Commands
In addition to the typical motion commands, the following commands are useful for resolver axes,
especially for resetting the position when used in rotational applications:

Zero Position/Set Target Command

Reset Position Command

Offset Positions Command


See also:

Resolver Configuration

Resolver LED Indicators

Resolver Wiring

Resolver Scaling

Resolver Specifications

Rotational Mode


6.5.2 Resolver Wiring

Note:

When positive voltage is sent to an axis’s drive, the axis must extend. The extend

direction is defined as the direction that causes the transducer to return increasing counts.

Use shielded twisted pairs for all connections to inputs and outputs. Route the resolver wiring
separate from other wiring.

RMC Resolver Input

Eight-Pin Plug-in Terminal Block

Pin

Function

R1

Reference Output +

Ref In

Reference In (normally not used)

R3

Reference Ouput -