Appendix A: Command Reference

A-85

XXXX|XXXX (XX)

High byte of requested data


Second scan:

Send on Command Strobe going high:

0000|XXXX|1110|0001 (0XE1)

Set End Step Number

Receive after Acknowledge:

XXXX|XXXX (XX)

Low byte of requested data

Send on Command Strobe going high:

0000|0000|0110|0011 (0063)

End Step Number of 99

Receive after Acknowledge:

XXXX|XXXX (XX)

High byte of requested data


Third scan:

Send on Command Strobe going high:

0000|XXXX|1110|0010 (0XE2)

Set Parameter to Modify

Receive after Acknowledge:

XXXX|XXXX (XX)

Low byte of requested data

Send on Command Strobe going high:

0000|0000|0000|0111 (0007)

Select Link Value

Receive after Acknowledge:

XXXX|XXXX (XX)

High byte of requested data


Fourth scan:

Send on Command Strobe going high:

0000|XXXX|1110|0011 (0XE3)

Set actual value

Receive after Acknowledge:

XXXX|XXXX (XX)

Low byte of requested data

Send on Command Strobe going high:

0000|0001|1101|1000 (01D8)

Link Value (500)

Receive after Acknowledge:

XXXX|XXXX (XX)

High byte of requested data