Plot time area, Status area, Plot time area -4 status area -4 – Delta RMC101 User Manual
Page 54: 4 plot time area, 5 status area
RMC100 and RMCWin User Manual
3-4
parameters for that axis will be displayed in WHITE.
Note:
When in Read-back Mode, you will notice that RED parameters will be replaced with
WHITE parameters as the current values are read from the RMC. This is done to indicate that
the values displayed match those used by the RMC.
For details on saving and loading parameters, see Changing Between Board Files.
3.2.4 Plot Time Area
This area is located in the top right portion of the main window. It holds the Plot Time field for
each axis. Refer to this topic for details on its use. This area is updated on startup and each time
RMCWin connects to a new RMC.
To the right of the PLOT TIME heading is a column for each axis. You can change these values
using the keyboard as described in Changing Data from the Keyboard. Changes are sent to the
RMC immediately.
3.2.5 Status Area
This area is located in the upper left portion of the main window. It holds the Status fields for each
axis. This area is updated constantly when an RMC is connected to RMCWin. Refer to the
following sections for details on these parameters:
Command Position
Target Position
Actual Position
Transducer Counts
Axis Status Word
Drive
Actual Speed
Null Drive
Step
Link Value
To the right of each of the Status field labels are the values for the status fields for each axis.
These values cannot be changed.