RMC100 and RMCWin User Manual

E-10

• If a Sensor DI/O is present, Sensor DI/O inputs 0-15 (or 0-7) are used.

• If no Sensor DI/O is present, but a Communication DI/O is present, Communication DI/O inputs

0-15 (or 0-7) are used.

• If neither Sensor nor Communication DI/O is present, then only CPU inputs 0-1 are used.

This link type is similar to Inputs, Single (Level/Edge) with the following differences:

Inputs, Multiple: allows up to 16 inputs to be evaluated at once.

Inputs, Single:

allows only one (1) input to be evaluated.

Inputs, Multiple: allows waiting for level events only.

Inputs, Single:

allows waiting for either a level or edge event.

Inputs, Multiple: for DI/O modules, usable inputs are limited to inputs 0-15 of one DI/O module.

Inputs, Single: any discrete input can be used on any DI/O module, except the CPU inputs when

the Communication DI/O is installed.

Using with the Link Type and Link Value Dialog Box

1. Under Link Type Category, select System-wide (Basic, non-axis).

2. Under Link Type, select Inputs, Multiple (Level only).

3. Under Link Condition, select whether you want to wait for all of the input events you are going to

enter, or any one of the events you will enter.

4. Under Link Condition, for each input, select whether you wish to have that input high, low, or

ignored.

Example:

If you wish to wait for both inputs 0 and 1 to be high, select that you want all of your input events to
be satisfied, for inputs 0 and 1, select the 1 option, and for all other inputs, select the X option.

Using without the Link Type and Link Value Dialog Box

1. Select the appropriate link type:

• If you want to wait for multiple inputs to be ON at once, select '['.

• If you want to wait for multiple inputs to be OFF at once, select ']'.

• If you want to wait for any one of several inputs to be ON at once, select '{ '.

• If you want to wait for any one of several inputs to be OFF at once, select '}'.

• If you want to wait for multiple input conditions including both ONs and OFFs, select '\'.

• If you want to wait for any one of several input conditions including both ONs and OFFs,

select '|'.

2. To enter the link value, you must understand binary. If you do not understand binary (actually,