Ethernet 5.2
Communications
5-151
N7:240-255
Same as above but for axis 7
Event Step Table Registers:
These registers can be read or written. When using the Allen-Bradley addressing scheme with
these registers, you must keep in mind that the Event Step Table is split over eight register files
(this is done because the SLC 5/05 only supports 256 words per file). Use the following table to
determine the register file for a given event step:
Event Step
(n)
Register
File (f)
Step Offset (r)
0-31
N9
( n - 0 ) x 8
32-63
N10
( n - 32 ) x 8
64-95
N11
( n - 64 ) x 8
96-127
N12
( n - 96 ) x 8
128-159
N13
( n - 128 ) x 8
160-191
N14
( n - 160 ) x 8
192-223
N15
( n - 192 ) x 8
224-255
N16
( n - 224 ) x 8
Note:
On Allen-Bradley PLCs, reads and writes that extend beyond the end of an RMC register
file will continue into the next file or files. This is particularly useful on the ControlLogix, which
allows reading large amounts of data with a single MSG block. For example, by reading 2048
integers starting at N9:0 in the RMC, the entire Event Step table can be read into the
ControlLogix.
The register map for addressing the fields in the event step table is as follows:
Allen-
Bradley
and SoftPLC
Register Description
N9:0
Step 0 Mode Word
N9:1
Step 0 Acceleration
N9:2
Step 0 Deceleration
N9:3
Step 0 Speed
N9:4
Step 0 Command Value
N9:5
Step 0 Command/Commanded Axes
N9:6
Step 0 Link Type/Link Next