Ethernet 5.2

Communications

5-163

:

:

2553 + n

Event Step for Axes n (0-7) on Input 15
Falling Edge

Status Map Registers:
This block of registers is only used by the Modbus Plus and PROFIBUS interfaces. Therefore,
these registers are unused by this Ethernet protocol.

TI505

Address

Register Description

2561-

2592

Status Map Entries

Plot Type Registers:
The plot type registers can be read or written. The values that are read indicate the extra plot
information in the current graph. Values written to these registers tell the controller which extra
plot information to obtain on the next plot. For these registers, the following values are used:

• 0: Extra position precision

• 1: Command and Command Value

• 2: Event Step and Link Value
• 3: Raw Transducer Counts

• 4: Internal Target and Actual Speeds
• 5: Integral Drive

For more information on these four types of plot information, see Selecting the Data to Plot and
Reading Plots from the Communication Module.

TI505

Address

Register Description

2625

Axis 0 plot type

2626

Axis 1 plot type

2627

Axis 2 plot type

2628

Axis 3 plot type

2629

Axis 4 plot type

2630

Axis 5 plot type

2631

Axis 6 plot type

2632

Axis 7 plot type

Digital (Discrete) I/O Registers: