beautypg.com

Following error, Auto stop, C.1.20 following error – Delta RMC101 User Manual

Page 785: C.1.21 auto stop

background image

Appendix C: Parameter Field Reference

C-15

If an axis Command Position is 10,000 and the In Position parameter is 30, the In Position bit will
be set when the axis is stopped and its Actual Position is between 9,971 and 10,029. The bit will
be cleared whenever the Actual Position is outside the range.

C.1.20 Following Error

Default: 250
Range: 0 to 65535

The Following Error determines how large the difference between the Target Position and Actual
Position can get before the Following Error bit is set in the Status word.

C.1.21 Auto Stop

Default: 0x1FE0 (Soft Stops enabled, Hard Stops enabled for Transducer Errors)
Click here for the Auto Stop Bit Map

The Auto Stop parameter controls the action taken on the rising edge of any of the axis' error bits
(the eight (8) most-significant bits in the Status word listed below). The user has control over
which error bits cause which levels of stop, or whether an error will cause a stop at all. The
default setting of all the AutoStops is Hard Stop, as described below.

During startup and tuning, you will typically need to set some AutoStops to Status Only to keep
halts from interfering with the tuning. After completeing the startup procedure, make sure to set
the AutoStops to setting that are safe for the machine operation.

Auto Stops are always active unless the axis is in Open Loop, in which case no Auto Stops will be
triggered even though error bits may be set.

Note:

AutoStops will not occur if the axis is in Open Loop!

The eight (8) most-significant bits in the Status word, as listed below, are the error bits, with the
exception of the Home Input status bit for Quadrature axes with Analog (QUAD) or Stepper
(STEP) output:

Fault

QUAD

STEP

All Others

7

Encoder Error/Fault

Encoder Error/Fault

No Transducer

6

Extend Limit

Extend Limit

Transducer Noise

5

Retract Limit

Retract Limit

Transducer
Overflow

4

Overdrive

Overdrive

Overdrive

3

Parameter Error

Parameter Error

Parameter Error

2

Home Input

Home Input

Pos./Press.
Overflow

1

Integrator Windup

Compensation
Timeout

Integrator Windup

0

Following Error

Following Error

Following Error

The available actions for each fault are listed below:

Status Only

This manual is related to the following products: