6.5.4 Resolver LED Indicators

The two LEDs above the Drive connector on the RMC’s Resolver interface card are axis status
LEDs. These LEDs will reflect the operational status of their corresponding axis according to the
following table.

LED Action

Axis Status

Continuous Red

No Transducer

Alternating Red/Green

The above error has not occurred,
and one or more of the below
errors have occurred and are
enabled in the Auto Stop:

Overdrive Error
Parameter Error
Position Overflow
Integrator Windup

Following Error

Continuous Green

Status good. None of the above
are true.


See also:

Resolver Overview

Resolver Configuration

Resolver Wiring

Resolver Specifications

Resolver Scaling

6.5.5 Resolver Specifications

For general specifications on the RMC, see RMC100 Specifications.