Delta RMC101 User Manual
Page 424
RMC100 and RMCWin User Manual
5-174
Last Parameter Error Registers:
Note:
To use these registers through Ethernet, you must have RMC100 CPU control firmware
dated 19990715 or later.
Each of these read-only registers holds the number of the last parameter error generated on an
axis. This is useful for determining the cause of the Parameter Error bit in the status word. For a
description of the values read from these registers, see Parameter Error Values.
S7 Address
Register Description
DB6.DBW48
Last parameter error on axis 0
DB6.DBW50
Last parameter error on axis 1
DB6.DBW52
Last parameter error on axis 2
DB6.DBW54
Last parameter error on axis 3
DB6.DBW56
Last parameter error on axis 4
DB6.DBW58
Last parameter error on axis 5
DB6.DBW60
Last parameter error on axis 6
DB6.DBW62
Last parameter error on axis 7
Firmware Date Registers:
Note:
To use these registers through Ethernet, you must have RMC100 CPU control firmware
dated 19990715 or later.
These read-only registers hold information about the firmware versions in the RMC100 CPU
module. The Boot and Loader firmware versions have no effect on the actual performance of the
RMC and therefore can usually be ignored.
S7 Address
Register Description
DB6.DBW64
Boot firmware month (MSB) and day (LSB)
DB6.DBW66
Boot firmware year
DB6.DBW68
Loader firmware month (MSB) and day (LSB)
DB6.DBW70
Loader firmware year
DB6.DBW72
Control firmware month (MSB) and day
(LSB)
DB6.DBW74
Control firmware year
DB6.DBW76
Control firmware Beta Code. This will be 0
for standard release firmware, 'B' for Beta
firmware, or 'SI' for Superimposed firmware.
DB6.DBW78
Feature code. This register is mainly
reserved for internal use but does have two