RMC100 and RMCWin User Manual

5-174

Last Parameter Error Registers:

Note:

To use these registers through Ethernet, you must have RMC100 CPU control firmware

dated 19990715 or later.
Each of these read-only registers holds the number of the last parameter error generated on an
axis. This is useful for determining the cause of the Parameter Error bit in the status word. For a
description of the values read from these registers, see Parameter Error Values.

S7 Address

Register Description

DB6.DBW48

Last parameter error on axis 0

DB6.DBW50

Last parameter error on axis 1

DB6.DBW52

Last parameter error on axis 2

DB6.DBW54

Last parameter error on axis 3

DB6.DBW56

Last parameter error on axis 4

DB6.DBW58

Last parameter error on axis 5

DB6.DBW60

Last parameter error on axis 6

DB6.DBW62

Last parameter error on axis 7

Firmware Date Registers:

Note:

To use these registers through Ethernet, you must have RMC100 CPU control firmware

dated 19990715 or later.
These read-only registers hold information about the firmware versions in the RMC100 CPU
module. The Boot and Loader firmware versions have no effect on the actual performance of the
RMC and therefore can usually be ignored.

S7 Address

Register Description

DB6.DBW64

Boot firmware month (MSB) and day (LSB)

DB6.DBW66

Boot firmware year

DB6.DBW68

Loader firmware month (MSB) and day (LSB)

DB6.DBW70

Loader firmware year

DB6.DBW72

Control firmware month (MSB) and day
(LSB)

DB6.DBW74

Control firmware year

DB6.DBW76

Control firmware Beta Code. This will be 0
for standard release firmware, 'B' for Beta
firmware, or 'SI' for Superimposed firmware.

DB6.DBW78

Feature code. This register is mainly
reserved for internal use but does have two