RMC100 and RMCWin User Manual

5-168

• RMC Register Map (Modbus Plus)

• RMC Register Map (PROFIBUS-DP Message Mode)

The Siemens S7-300 and S7-400 families of PLCs, when equipped with the CP 343-1 TCP or CP
443-1 TCP modules, can communicate with the RMC Ethernet module. From the S7, the RMC
registers are viewed as data block (DB) registers.

Status Registers:
These registers can only be read; writes are ignored.

S7 Address

Register Description

DB1.DBW0

Axis 0 Command Position

DB1.DBW2

Axis 0 Target Position

DB1.DBW4

Axis 0 Actual Position

DB1.DBW6

Axis 0 Transducer Counts

DB1.DBW8

Axis 0 Status Word

DB1.DBW10

Axis 0 Drive

DB1.DBW12

Axis 0 Actual Speed

DB1.DBW14

Axis 0 Null Drive

DB1.DBW16

Axis 0 Event Step

DB1.DBW18

Axis 0 Link Value

DB1.DBW20-38

Same as above but for axis 1

DB1.DBW40-58

Same as above but for axis 2

DB1.DBW60-78

Same as above but for axis 3

DB1.DBW80-98

Same as above but for axis 4

DB1.DBW100-

118

Same as above but for axis 5

DB1.DBW120-

138

Same as above but for axis 6

DB1.DBW140-

158

Same as above but for axis 7

Command Registers:
These registers can be read or written.