RMC100 and RMCWin User Manual

5-70

• RMC Register Map (Siemens S7)

• RMC Register Map (Modbus Plus)

• RMC Register Map (PROFIBUS-DP Message Mode)

Allen-Bradley offers several Ethernet and serial solutions for its ControlLogix, SLC, PLC-5, and
SoftLogix 5 controllers. In addition, SoftPLC emulates the PLC-5 and therefore also uses Allen-
Bradley's Ethernet protocol. Over this protocol, the RMC's registers are broken into a number of
integer files. Each integer file used (N7, N9-N18, L19, N20-N255) is configured to be the
maximum size allowed on a SLC 5/05 file: 256 elements: Nf:0-255. For details on reading and
writing these registers, see the following topics:

• Using Allen-Bradley Controllers with the RMC ENET

• Using SoftPLC's SoftPLC with the RMC ENET

• Using DF1 (Full- and Half-Duplex) with the RMC SERIAL

Status Registers:
These registers can only be read; writes are ignored.

Allen-

Bradley

and SoftPLC

Register Description

N7:0

Axis 0 Command Position

N7:1

Axis 0 Target Position

N7:2

Axis 0 Actual Position

N7:3

Axis 0 Transducer Counts.

Note:

See the Transducer Counts (32-bit)

Registers section below for a way to read
32-bit counts instead of 16-bit counts.

N7:4

Axis 0 Status Word

N7:5

Axis 0 Drive

N7:6

Axis 0 Actual Speed

N7:7

Axis 0 Null Drive

N7:8

Axis 0 Event Step

N7:9

Axis 0 Link Value

N7:10-19

Same as above but for axis 1

N7:20-29

Same as above but for axis 2