Delta RMC101 User Manual
Page 533
Communication Tasks 5.9
Communications
5-283
Axis 0 Point
Count
14337
14336
N56:0
V14000
DB200.DBW0
Axis 0 Point
Table**
14338-
15360
14337-
15359
N56:1-
N59:255
V14001-
15777
DB200.DBW2-
2046
Axis 1 Point
Count
15361
15360
N60:0
V16000
DB201.DBW0
Axis 1 Point
Table**
15362-
16384
15361-
16383
N60:1-
N63:255
V16001-
17777
DB201.DBW2-
2046
* The Interval Table contains 1022 intervals max.
** The Point Table contains 1023 points max.
Static Format with 3 or 4 Spline-Capable Axes
Register
Description
Modbus
and
TI505
PROFIBUS
Allen-
Bradley
and
SoftPLC
DL205/405
Siemens
S7-300/400
Axis 0
Interval
Table
Format
12289
12288
N48:0
V10000
DB192.DBW0
Axis 0
Interval
Table*
12290-
12800
12289-
12799
N48:1-
N49:255
V10001-
10777
DB192.DBW2-
1022
Axis 1
Interval
Table
Format
12801
12800
N50:0
V11000
DB193.DBW0
Axis 1
Interval
Table*
12802-
13312
12801-
13311
N50:1-
N51:255
V11001-
11777
DB193.DBW2-
1022
Axis 2
Interval
Table
Format
13313
13312
N52:0
V12000
DB194.DBW0
Axis 2
Interval
Table*
13314-
13824
13313-
13823
N52:1-
N53:255
V12001-
12777
DB194.DBW2-
1022
Axis 3
Interval
Table
Format
13825
13824
N54:0
V13000
DB195.DBW0
Axis 3
13826-
13825-
N54:1-
V13001-
DB195.DBW2-