MDT 6.2

Transducer Interface Modules

6-27

Drive Outputs

Range

±10 V @ 5 mA (2 kW or greater load)

(For current drive, use the VC2100
accessory:
±10 mA to ±200 mA in 10 mA steps)

Tolerance

At 10 V: +200 mV, -100 mV
At 0 V: ±50 mV
At -10 V: +100 mV, -200 mV

Resolution

12 bits

Output isolation

750 VDC, optically isolated

Overload

protection

One-second short-circuit duration

Overvoltage

protection

Outputs are protected by clamp diodes


See also:

MDT Overview

MDT Wiring

MDT Configuration

MDT LED Indicators

6.2.6 MDT Scaling

Defining the Valid 16-bit Position Range
For general scaling information, see the Scaling Overview topic.

Because the RMC uses 16-bit positions, positions must all fit within a range of 65,536 position
units. Because position units are user definable, this range does not limit most applications. See
the section below on defining position units.

For MDT axes, the Offset parameter is used with the Scale parameter to define the position
range. If the Scale parameter is negative, then the position range extends from the Offset value
minus 65535 up to the Offset value. If the Scale parameter is non-negative, then the position
range extends from the Offset value up to the Offset value plus 65535. The following chart
summarizes this concept:

Scale

Min. Position

Max. Position

< 0

Offset - 65535

Offset

³ 0

Offset

Offset + 65535