Mdt scaling, Mdt scaling -27, 6 mdt scaling – Delta RMC101 User Manual
Page 571
MDT 6.2
Transducer Interface Modules
6-27
Drive Outputs
Range
±10 V @ 5 mA (2 kW or greater load)
(For current drive, use the VC2100
accessory:
±10 mA to ±200 mA in 10 mA steps)
Tolerance
At 10 V: +200 mV, -100 mV
At 0 V: ±50 mV
At -10 V: +100 mV, -200 mV
Resolution
12 bits
Output isolation
750 VDC, optically isolated
Overload
protection
One-second short-circuit duration
Overvoltage
protection
Outputs are protected by clamp diodes
See also:
MDT Overview
MDT Wiring
MDT Configuration
MDT LED Indicators
6.2.6 MDT Scaling
Defining the Valid 16-bit Position Range
For general scaling information, see the Scaling Overview topic.
Because the RMC uses 16-bit positions, positions must all fit within a range of 65,536 position
units. Because position units are user definable, this range does not limit most applications. See
the section below on defining position units.
For MDT axes, the Offset parameter is used with the Scale parameter to define the position
range. If the Scale parameter is negative, then the position range extends from the Offset value
minus 65535 up to the Offset value. If the Scale parameter is non-negative, then the position
range extends from the Offset value up to the Offset value plus 65535. The following chart
summarizes this concept:
Scale
Min. Position
Max. Position
< 0
Offset - 65535
Offset
³ 0
Offset
Offset + 65535