Modbus Plus 5.3

Communications

5-205


Status
Type

Word

Index

MSB

Node

Global
Input

0

16

15

14

13

12

11

10

9

1

32

31

30

29

28

27

26

25

2

48

47

46

45

44

43

42

41

3

64

63

62

61

60

59

58

57

Specific
Output

4

16

15

14

13

12

11

10

9

5

32

31

30

29

28

27

26

25

6

48

47

46

45

44

43

42

41

7

64

63

62

61

60

59

58

57

Specific
Input

8

16

15

14

13

12

11

10

9

9

32

31

30

29

28

27

26

25

10

48

47

46

45

44

43

42

41

11

64

63

62

61

60

59

58

57

Control Block
The nine control-block registers are assigned in a Peer Cop Health operation as shown:

Register

Content

1st

Operation

: 9

2nd

Error Status

: This register is filled by the

operation. See MSTR Block Error Codes for a
complete list.

3rd

Length

: Indicates the number of words to transfer.

4th

Word Index

: Gives the index of the first Peer Health word

to read.

5th-9th Routing 1-5: Unused. Set zeros.

Example
Suppose that we have an RMC device on a Modbus Plus network with a node address of 3. We
want to set a coil called ”r;disconnected” when the RMC is not found on the network. We will read
one of the four Peer Cop Global Input Health registers into register 400200. We must first choose
a location for the 9-register control block. In this example, 400130 to 400138 is the location. The
following network would be used: