NETGEAR M4350-24F4V 24-Port 10G SFP+ Managed AV Network Switch User Manual
Page 903
4. Enter admin as the user name, enter your local device password, and click the Login
button.
The first time that you log in, no password is required. However, you then must
specify a local device password to use each subsequent time that you log in.
The System Information page displays.
5. Select Maintenance > Troubleshooting > Traceroute IPv4.
The Traceroute IPv4 page displays.
6. In the IP Address/Hostname field, enter the IP address or host name of the device
for which the path must be discovered.
7. In the Probes Per Hop field, enter the number of probes per hop.
The default value is 3. The range is from 1 to 10.
8. In the Max TTL field, enter the maximum time to live (TTL) for the destination.
The default value is 30. The range is from 1 to 255.
9. In the Init TTL field, enter the initial TTL to be used.
The default value is 1. The range is from 1 to 255.
10. In the MaxFail field, enter the maximum number of failures allowed in the session.
The default value is 5. The range is from 1 to 255.
11. In the Interval (secs) field, enter the time between probes in seconds.
The default value is 3. The range is from 1 to 60.
12. In the Port field, enter the UDP destination port for the probe packets.
The default value is 33434. The range is from 1 to 65535.
13. In the Size field, enter the size of the probe packets.
The default value is 0. The range is from 0 to 39936.
14. From the Source menu, as an option, you can select the IP address or interface that
must be used to send probe packets:
•
None: The source address of the probe packet is the address of the default egress
interface.
•
IP Address: The source IP address that must be used when probe request packets
are sent. With this selection, the IP Address field displays and you must enter
the IPv4 address that must be used as the source.
•
Interface: The interface that must be used when probe request packets are sent.
The Interface menu displays, but the only available selection from the menu is
Network.
15. Click the Apply button.
Main User Manual
903
Maintenance and
Troubleshooting
Fully Managed Switches M4350 Series Main User Manual