NETGEAR M4350-24F4V 24-Port 10G SFP+ Managed AV Network Switch User Manual
Page 57
The standby management switch becomes the stack management switch.
The following table describes the view-only fields on the page.
Description
Field
NSF Summary section
Indicates if NSF is enabled on the standby management switch
Operational Status
The reason of the most recent NSF switchover:
• Power On: The stack management switch restarted, for example because of a power
cycle or the execution of a reload command, and the standby management switch
took over.
• Cold Admin Move: The stack management switch reset all information without
actually restarting, the standby management switch took over and began from a
preinitialized state, and no data is retained from before the switchover.
• Warm Admin Move: You pressed the Initiate Failover button or a CLI command
for the standby management switch to take over.
• Auto Warm: The stack management switch restarted because of a failure and the
standby management switch took over.
• Auto Cold: The standby management switch took over and user data traffic was
interrupted. This situation might be caused by multiple failures occurring close
together.
Last Startup Reason
The period since the current management switch became the active management
switch. For the standby management switch, the value is set to 0.
Time Since Last Restart
Indicates if a switchover from the stack management switch to the standby management
switch is in progress. A restart is not considered complete until all information is fully
reconciled.
Restart In Progress
The stack management switch is synchronized with the standby management switch,
and the stack management switch can be restarted, if needed.
Warm Restart Ready
Copy of Running Configuration to Backup Unit
The status of copying the running configuration to the standby management switch
Status
The period since the running configuration was copied to the standby management
switch
Time Since Last Copy
NSF Support on Unit
The unit ID of the switch in the stack
Unit ID
Displays if the switch in the stack is capable of supporting NSF
NSF Support
Main User Manual
57
Manage Stacking
Fully Managed Switches M4350 Series Main User Manual