beautypg.com

Send an ipv6 traceroute – NETGEAR AV Line M4250 GSM4210PX 8-Port Gigabit PoE+ Compliant Managed AV Switch with SFP (220W) User Manual

Page 760

background image

12. In the Port field, enter the UDP destination port for the probe packets.

The default value is 33434. The range is from 1 to 65535.

13. In the Size field, enter the size of the probe packets.

The default value is 0. The range is from 0 to 39936.

14. From the Source menu, as an option, you can select the IP address or interface that

must be used to send probe packets:

• None: The source address of the probe packet is the address of the default egress

interface.

• IP Address: The source IP address that must be used when probe request packets

are sent. With this selection, the IP Address field displays and you must enter the
IPv4 address that must be used as the source.

• Interface: The interface that must be used when probe request packets are sent.

The Interface menu displays, but the only available selection from the menu is
Network.

15. Click the Apply button.

A traceroute request is sent to the specified IP address or host name. The results are
displayed below the configurable data in the Results field.

Send an IPv6 traceroute

You can configure the switch to send a traceroute request to a specified IPv6 address
or host name. You can use this to discover the paths that packets take to a remote
destination. When you send a traceroute, the switch displays the results below the
configurable data.

If a reply to the traceroute is received, the following message displays:

traceroute to x:y::z:w (x:y::z:w), maxTTL hops max, size byte packets

initTTL x:y::z:w (x:y::z:w) 0.000 ms * 0.000 ms

initTTL+1 x:y::z:w (x:y::z:w) 0.000 ms * 0.000 ms

initTTL+2 x:y::z:w (x:y::z:w) 0.000 ms * 0.000 ms

To send an IPv6 traceroute:

1. Launch a web browser.

2. In the address field of your web browser, enter the IP address of the switch.

The login page displays.

Main User Manual

760

Maintenance and
Troubleshooting