8. If you are adding a user account, in the User Name field, enter a name for the user

account.
The name can contain up to 31 alphanumeric characters. After you add the user
account, you cannot change the name.

9. From the Edit Password menu, select to use a password or no password at all for

the new user account:

• Enable: The Password and Confirm Password fields are unmasked so that you

can specify a unique password for the new user account:

In the Password field, specify a password from 8 to 64 characters.

In the Confirm Password field, specify the password again.

• Disable: The Password and Confirm Password fields are masked and you cannot

specify a password for the new user account.

By default, the selection is Disable, which means that no password is used and the
password fields are masked out.

10. From the Group menu, select at least one captive portal group.

To assign a user account to more than one group, press the Control key and click
each group. By default, a new user account is assigned to the default group with ID
1.

11. In the Session Timeout field, enter the period in seconds that a user is permitted

to remain connected to the network.
After the session time-out period is exceeded, the user is logged out automatically.
The default is 0, which means that the session does not time out. The range is from
0 to 86400 seconds.

12. In the Idle Timeout field, enter the period in seconds that the switch waits before

terminating an idle session and logging out the user.
The default is 0, which means that an idle session does not time out. The range is
from 0 to 900 seconds.

13. In the Max Bandwidth Down field, enter the maximum rate, in bits per second, at

which a client can receive data from the network.
A value of 0 indicates that the global configuration must be used. The range is from
0 to 536870911 bps.

14. In the Max Bandwidth Up field, enter the maximum rate, in bits per second, at which

a client can send data into the network.
A value of 0 indicates that the global configuration must be used. The range is from
0 to 536870911 bps.

Main User Manual

642

Manage Switch Security

AV Line of Fully Managed Switches M4250 Series Main User Manual