beautypg.com

Xcvr_rx_linear_equalizer_control, Xcvr_gt_rx_common_ mode_voltage, Xcvr_gt_rx_ctle – Altera Transceiver PHY IP Core User Manual

Page 636

background image

Assign To

Pin - RX serial data

XCVR_RX_LINEAR_EQUALIZER_CONTROL

Pin Planner and Assignment Editor Name

Receiver Linear Equalizer Control

Description

Static control for the continuous time equalizer in the receiver buffer. The equalizer has 16 settings from

0–15 corresponding to the increasing AC gain.

Options

1 –16

Assign To

Pin - RX serial data

XCVR_GT_RX_COMMON_ MODE_VOLTAGE

Pin Planner and Assignment Editor Name

GT receiver Buffer Common Mode Voltage

Description

Receiver buffer common-mode voltage. This parameter is only for GT transceivers.
Note: Contact Altera for using this assignment.

Related Information

How to Contact Altera

on page 21-42

XCVR_GT_RX_CTLE

Pin Planner and Assignment Editor Name

GT Receiver Linear Equalizer Control

Description

Static control for the continuous time equalizer in the receiver buffer. The equalizer has 9 distinct settings

from 0-8 corresponding to increasing AC gain. This parameter is only for GT transceivers.

Options

0-8

Assign To

Pin - RX serial data

19-42

XCVR_RX_LINEAR_EQUALIZER_CONTROL

UG-01080

2015.01.19

Altera Corporation

Analog Parameters Set Using QSF Assignments

Send Feedback