Rate match fifo parameters, Rate match fifo parameters -9 – Altera Transceiver PHY IP Core User Manual
Page 222

Name
Value
Description
Enable run length violation
checking
On/Off
If you turn this option on, you can specify the
run length which is the maximum legal
number of contiguous 0s or 1s.
Run length
40-640
Specifies the threshold for a run-length
violation.
Table 9-6: More Information About Word Aligner Functions
PMA-PCS Interface Width (bits)
Word Alignment
Mode
Word Alignment
Pattern Length (bits)
Word Alignment Behavior
8
Manual alignment
8, 16
User-controlled signal starts
alignment process.
Alignment occurs once
unless signal is re-asserted.
10
Manual alignment
7 , 10
User-controlled signal starts
alignment process.
Alignment occurs once
unless signal is re-asserted.
Automatic
synchronized state
machine
Data must be 8B/10B
encoded and aligns to
selected word aligner
pattern.
16
Manual alignment
8 , 16, 32
User-controlled signal starts
alignment process.
Alignment occurs once
unless signal is re-asserted.
20
Manual alignment
7, 10, 20
User-controlled signal starts
alignment process.
Alignment occurs once
unless signal is re-asserted.
Automatic
Synchronized State
Machine
7, 10, 20
Automatically selected word
aligner pattern length and
pattern.
Related Information
•
•
•
Rate Match FIFO Parameters
The rate match FIFO compensates for small clock frequency differences between the upstream transmitter
and the local receiver clocks by inserting or removing skip (SKP) symbols or ordered-sets from the inter-
packet gap (IPG) or idle streams. It deletes SKP symbols or ordered-sets when the upstream transmitter
UG-01080
2015.01.19
Rate Match FIFO Parameters
9-9
Custom PHY IP Core
Altera Corporation